The proposed change would allow the pulser to run in an alternative mode with a series of STEP1 and STEP2 pulses (1-32) followed by a single DISCHARGE pulse.
See diagrams:
We agreed that the number of step 1/2 pulse pairs would be 1-32, with spacing programmable and a bit mask with 32 bits to specify the positions of the step 2 pulses.
Parameter | Bits | Description |
CHARGE_START | 21 | delay to start of STEP1 |
STEP1_END | 21 | delay to end of STEP1 |
STEP2_START | 21 | delay to start of STEP2 |
CHARGE_END | 21 | end of STEP1 (single-step) or STEP2 (two-step) |
MODE | 1 | 0=single step 1=two step |
NPULSE | 5 | number of STEP1/STEP2 pulses 1-32 |
MASK2 | 32 | bit mask to enable STEP2 pulses individually |
(bit 0 = first pulse) |