wiki:Blade_notes

Historical notes for blades

ID Location Remote Access? ---------- CM? Cirex Notes ECOs
001 BU (assembly room) no K 98716 Hard-wired 12V on, misc on, zynq bank IO on. Pulldown on zynq_en. 1k pulldown on U15 pin 1. Jumper on switch en to 3.3V. Removed R35 and R40. Test paused after zynq booted successfully. 1, 2
002 BU (in Shelf for now) no - 98724 for show. Test paused after zynq booted successfully. Test completed. 1, 2
003 BU (assembly room) no - 1k pulldown on U15. switch fix. J28 has a connector, should be removed. LEDs lit up incorrectly, same as SM004. Stopped testing. 1, 2
004 BU (table) no - 98719 Resistor between R95 and R92 came off before step "put in zynq." LEDs lit up incorrectly. Stopped testing. Trial 2: Numerous LEDs lit up incorrectly at the same step (6: put in zynq). Stopped again. 1, 2
005 Cornell no - 98720 LEDs hot-wired permanently on. Test completed. 1, 2
006 BU yes K+V 98721 Test paused after zynq booted successfully. Test completed. 1, 2
007 Amherst - - 98723 Missing LED after all ECOs completed. Resoldered new LED. Test completed. 1, 2
008 CERN TIF no - 98717 Missing LED after all ECOs completed. Resoldered new LED. Test paused after zynq booted successfully. Test completed. 1, 2
009 Cornell - - 98725 Test paused after zynq booted successfully. Test completed. 1, 2
010 CERN TIF - ? 98718 Test paused after zynq booted successfully. Test completed. 1, 2
Last modified 6 years ago Last modified on Oct 28, 2019, 12:54:29 PM