    4 == HVPulser Rev A testing 1/16/20 ==
     4== Filament Supply Rev A testing 1/31/20 ==
    55
    66'''Setup:''' The attached photos show the setup used for testing the Filament Supply. For this test 120VAC was supplied to the board through a 6-pin Molex connector from a variac. For the first test the BNC used to supply input voltage was capped with a 100ohm resistor to ground. For the other test, the input voltage was supplied across this BNC connector. A 25ohm 10W resistor was used as a test load.[[BR]][[Image(http://gauss.bu.edu/svn/tof-system/Gallery/2020-01-31/Setup.jpg, 15%, link=[http://gauss.bu.edu/svn/tof-system/Gallery/2020-01-31/Setup.jpg])]][[Image(http://gauss.bu.edu/svn/tof-system/Gallery/2020-01-31/Load.jpg, 15%, link=[http://gauss.bu.edu/svn/tof-system/Gallery/2020-01-31/Load.jpg])]]